Installation instructions – REMKO CMF-120-1P User Manual

Page 13

Advertising
background image

Outdoor unit CMT 120-1P

Indoor unit

CMT 120-1P

Fan

Outdoor area

Refrigerant lines

3

/

8

" and

5

/

8

"

Mains cable

Indoor unit

(3x1.5mm

2

)

Indoor area

condensate drain

(must be designed to be frost proof!)

* Mains supply

230V/1~50Hz 25A

(3x4 mm

2

)

Control cable (4x1 mm

2

)

Outdoor unit CMF 120-1P

Fan

condensate drain

(must be designed to be frost proof!)

Hot-water supply

and return pipes

(DN 25)

Mains cable

Electric booster

heater

3x(3x1.5 mm

2

)

Mains cable

Indoor unit

(3x1.5mm

2

)

Mains cable

Electric booster

heater (optional)

3x(3x1.5 mm

2

)

condensate drain

Refrigerant lines

3

/

8

" and

5

/

8

"

Control cable (4x1 mm

2

)

Inlet for
Heating (DN 25)

Common
Return pipe (DN 25)

Supply pipe for hot-
water tank (DN 25)

Indoor unit

CMF 120-1P

Installation instructions

The indoor and outdoor modules
have to be connected with
refrigerant lines of dimensions

3

/

8

"

(ca. 16 mm) and

5

/

8

" (ca. 10 mm).

A four-wire control cable has to be
laid between the two modules.

Both the indoor and outdoor
modules require a separate power
supply.

* Mains supply

230V/1~50Hz 25A

(3x4 mm

2

)

System Layout CMF 120-1P / CMT 120-1P

13