REMKO CMF / CMT

Terminal block/legend

Termi-

nal

Connection layout (low-voltage sensor)

X3.

Earth

X3.1

CAN-Bus H

X3.2

CAN-Bus +

X3.3

CAN-Bus L

X3.4

CAN-Bus -

X3.5

eBus - (nominal output in % above 0-10 V -signal)

X3.6

eBus + (nominal output in % above 0-10 V -signal)

X3.7

F17 Return sensor (cooling-control sensor)

X3.8

F15 sensor (option: flow-volume regulator)

X3.9

F14 Solar-collector or Solid-fuel-boiler sensor

(pt 1000)

X3.10

(not connected)

X3.11

F12 Lower buffer storage

(reference sensor, solar or solid-fuel boiler)

X3.12

F11 Inlet sensor, heat pump or heating-circuit 1

X3.13

F9 External sensor

X3.14

F8 Collector sensor, common inlet (heating-control sensor)

X3.15

F6 Warm-water-storage sensor

X3.16

F5 Inlet sensor, heating-circuit 2 (mixing circuit)

X3.17

F3 (not connected)

X3.18

F2 (not connected)

X3.19

F1 (not connected)

X3.20

Liquid-temperature sensor, cooling circuit

X3.21

Undercooling temperature, cooling circuit

The connection terminals X1.4 through x1.9, as
well as X2.15 and X2.18 are available only when
the electric booster heater is installed or when it
is standard equipment (CMT)

NOTE

Termi-

nal

Connection layout (outputs)

X2.1

Control cable, outdoor- and indoor module - S1

X2.2

Control cable, outdoor- and indoor module - S2

X2.3

Control cable, outdoor- and indoor module - S3

X2.4

Enable 2. Heat generator (common contact,

optionally potential free or 230 V feed over the

bridge at X2.19)

X2.5

Enable 2. Heat source (open)

X2.6

Enable 2. Heat source (closed)

X.2.7

Switching valve 2. Heat generator - OPEN

X2.8

Switching valve 2. Heat generator - N

X2.9

Switching valve 2. Heat generator - OFF

X2.10

Mixer, heating circuit 2 - OPEN

X2.11

Mixer, heating circuit 2 - N

X2.12

Mixer, heating circuit 2 - CLOSED

X2.13

Power plant enable/disable

X2.14

Power plant enable/disable

X2.15

Contactor K6-A1/L‘, 6 kW elec. booster heater

X2.16

Flow monitor

X2.17

Flow monitor

X2.18

Contactor K6 and K8-A2/N1.2, elec. booster

heater

X2.19

Live phase - L'

X2.20

Live phase - L'

X2.21

Live phase - L'

X2.22

Circulation pump, heating circuit 1 - L

X2.23

Circulation pump, heating circuit 1 - N

X2.24

Circulation pump, heating circuit 1 - PE

X2.25

Circulation pump, heating circuit 2 - L

X2.26

Circulation pump, heating circuit 2 - N

X2.27

Circulation pump, heating circuit 2 - PE

X2.28

Switching valve, warm water L" - black

X2.29

Switching valve, warm water N - grey

X2.30

PE

Termi-

nal

Connection layout (supply)

X1.1

Power supply, indoor module - L

X1.2

Power supply, indoor module - N

X1.3

Power supply, indoor module - PE

X1.4

Power supply, E-heater - L1

(optional for CMF Series).

X1.5

Power supply, E-heater - N

(optional for CMF Series).

X1.6

Power supply, E-heater - PE

(optional for CMF Series).

X1.7

Power supply, E-heater - L1

(optional for CMF Series).

X1.8

Power supply, E-heater - L1

(optional for CMF Series).

X1.9

PE

X1.10

PE

X1.11

Power supply, E-heater - N

(optional for CMF Series).

X1.12

Power supply, E-heater - N1

(optional for CMF Series).

Termi-

nal

Connection layout (outputs) continuation

X2.31

Switching valve, cooling L" - black

X2.32

Switching valve, cooling N - grey

X2.33

PE

X2.34

Circulation pump, cooling - L

X2.35

Circulation pump, cooling - N

X2.36

Circulation pump - PE

X2.37

Circulation- or solar pump - L

X2.38

Circulation- or solar pump - N

X2.39

Circulation- or solar pump - PE

X2.40

Charge pump, indoor module - L

X2.41

Charge pump, indoor module - N

X2.42

Charge pump, indoor module - PE