Remko cmf / cmt – REMKO CMF-120-1P User Manual

Page 14

Advertising
background image

REMKO CMF / CMT

Ö

Outdoor unit CMT 160-1P

Indoor unit

CMT 160-1P

Fan

Outdoor area

Refrigerant lines

3

/

8

" and

5

/

8

"

Mains cable

Indoor unit

(3x1.5mm

2

)

Indoor area

condensate drain

(must be designed to be frost proof!)

* Mains supply

230V/1~50Hz 32A

(3x6 mm

2

)

Control cable (4x1 mm

2

)

Outdoor unit CMF 160-1P

Fan

condensate drain

(must be designed to be frost proof!)

Hot-water supply

and return pipes

(DN 25)

Mains cable

Electric booster

heater

3x(5x1.5 mm

2

)

Mains cable

Indoor unit

(3x1.5mm

2

)

Mains cable

Electric booster

heater (optional)

3x(5x1.5 mm

2

)

condensate drain

Refrigerant lines

3

/

8

" and

5

/

8

"

Control cable (4x1 mm

2

)

* Mains supply

230V/1~50Hz 32A

(3x6 mm

2

)

Inlet for

Heating (DN 25)

Common

Return pipe (DN 25)

Supply pipe for hot-

water tank (DN 25)

Indoor unit

CMF 160-1P

System Layout CMF 160-1P / CMT 160-1P

14

Advertising