The wall bracket is to be
attached to the wall with the
fasteners supplied and the
indoor module hooked onto it.

The wall must possess sufficient
load-bearing capacity for the
weight of the indoor module.

Ensure that the wall bracket
is installed level.

The indoor module can be
aligned precisely by means of
the adjustment screws on the
back of the housing.

The indoor module is to
be mounted in such a way
that all of the sides have
sufficient space for purposes
of installation and maintenance.
It is equally important that
there is sufficient space above
the device for installing the
safety assembly.

Only fasteners suitable for the
given application may be used.

NOTE

Installation or setting up the
indoor module

Wall mounting CMF 320 Duo

The device may be attached
only to a load-bearing structure
or wall. Ensure that the outdoor
modules are installed only
vertically. The installation site
should be well ventilated.

To minimise noise, install floor
consoles with vibration dampers
and a considerable distance
from acoustically-reflective
walls to minimise noise.

The minimum clearances
specified on the next page
should be maintained when
carrying out the installation.
These minimum distances serve
to ensure unrestricted air intake
and exhaust.
Additionally, there must be
adequate space available for
installation, maintenance and
repair.

If the outdoor modules are
erected in an area of strong
winds, then the device must be
protected against them. The
snow line is to be observed
during installation (see figures).

The outdoor modules must
always be installed on vibration
dampers. Vibration dampers
prevent the transmission of
vibrations through the floor or
walls.

A heated, condensate catch-
pan ensures that condensation
from the pan can drain off.
Ensure that the condensate
is prevented from freezing so
that it can drain off (gravel,
drainage). The Water Ecology
Act is to be observed.

Outdoor-module installation location

If there is insufficient space
under the device for the
refrigerant lines, then the pre-
cut recesses can be removed
from the lower enclosure-panel
and the pipes guided through
these openings.

During installation, add about
20 cm to the expected snow
depth to guarantee unimpeded
intake and exhaust of outdoor
air year round.

The installation site of the
outdoor modules should be
agreed together with the
operator primarily so that
operating noise is minimised
and not in terms of “short
routes”. Thanks to the split-
design technology there
are a great deal of different
installation options with almost
identical efficiency available.