Troubleshooting and customer service – REMKO CMF 320 Duo User Manual

Page 29

Advertising
background image

Troubleshooting and customer service

The unit has been manufactured using state-of-the-art production methods and tested several times to ensure
its correct function. However, in the event that malfunctions should occur, the device should be checked against
the following list. Please inform your dealer if the unit is still not working correctly after all of the functional
checks have been performed.

Fault

Possible causes

Remedial measures

The heat pump does

not start or switches

itself off

Power outage, under-voltage

Check the voltage and, if necessary, wait for it

to come back on

Defective mains fuse

Master switch off

Exchange mains fuse, master switch on

Damaged mains cable

Repair by specialist firm

Power company off-period

Wait until the power-company off-period is

over and the heat pump starts up as required

Operational temperature limits too

low or too high

Observe temperature ranges

Set-point temperature exceeded

Incorrect mode

The set-point temperature has to be higher

than the heat-source temperature, check mode

Clamp fault

Control cable S1-S2-S3-PE

Disconnect the outdoor module, then establish

the correct clamp order using the connection

plan Re-establish voltage to the outdoor

module. Also make sure that the protective

earth is connected correctly.

Heat circuit pump

fails to switch off

Incorrect pump switching

Arrange to have pump switching checked in

"heating circuit" expert level

Heat circuit pumps

fail to switch on

Incorrect mode set

Check mode

Control PCB fuse in indoor module

switching cabinet faulty

Exchange the fuse on the left side of the control

PCB

Incorrect heating program set

Check heating program We recommend the

operating mode "heat" in the cold heating

season

Temperature overlapping, e.g.

external temperature greater than

room temperature

Observe temperature ranges

Troubleshooting

A corresponding error code
appears on the heat pump
manager display in the event
of a fault in the heating system.
The meanings of the displayed
error codes can be taken from

the table on the next page.
The system should be restarted
after a brief shut-down after the
fault has been rectified (turn the
mode switch off then on again).

Subsequently the heat-pump
manager will re-start, automatically
reconfigure and continue to
operate with the set values.