Climatic region: -10°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

4,15

4,03

3,82

3,87

3,74

3,60

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

4,07

3,95

3,91

3,78

3,64

3,50

Climatic region: -12°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

4,07

3,95

3,82

3,79

3,68

3,53

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

3,98

3,86

3,73

3,69

3,56

3,43

Climatic region: -14°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

4,00

3,89

3,77

3,74

3,61

3,49

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

3,92

3,80

3,68

3,64

3,52

3,39

Climatic region: -16°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

3,89

3,78

3,67

3,64

3,52

3,39

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF 320

2,5

3,9

4,4

3,79

3,67

3,56

3,52

3,41

3,28

Note: A differential of 7K has a standard floor-heating layout, a differential of 10K is typical for a radiator system
Additional key data: a heating-threshold temperature of 15°C for old construction and 12°C in new construction, a differential at the condenser

(test-bench measurements: 5K)

Annual performance number for CMF 320 Duo

Mode: single energy source, parallel with a switch-over point of -5°C

50

Advertising