Circulation operation

The fresh water station is (optionally) equipped

with a circulation pump. Three possible operating

modes are stored in the controller to operate the

circulation pump (also see the operating instruc-

tions of the controller).

n

Pulse-controlled operation (as necessary /

requirement):
Actuating a hot water dispensing connection

for a short time (dispensing impulse: ~2 sec-

onds) starts the circulation pump. The circula-

tion pump then runs for a few minutes (adjust-

able).

n

Time-dependent operation:
Operation of the circulation pump can be

adjusted on a weekly timer within a freely-

selectable period. In this operating mode, cir-

culation begins at the start of the period that is

set. Circulation is deactivated after the set

period expires.

n

Temperature-dependent operation:
In this operating mode, circulation is only

started if the temperature falls below the min-

imum temperature that can be set on the circu-

lation temperature probe within the operation

period. Circulation is deactivated after the

adjustable target temperature is reached or

after the set period expires.

Any of the operating modes can be combined, e.g.

time-dependent and temperature-dependent oper-

ation. In this case, circulation is only active if the

temperature falls below the temperature on the cir-

culation temperature probe and the time window is

active. Outside this time window, the circulation

pump can be activated via a dispensing pulse if

pulse-controlled operation is also activated.

NOTICE!

In the delivered state, circulation is not acti-

vated (see the operating instructions of the

controller). If the REMKO circulation pump is

installed, the operating mode must be activated

urgently. The speed of the circulation pump

must be specified via the PWM signal. ( Fac-

tory setting: 0 % ).

6

Assembly and installa-

tion (specialist)

DANGER!

Danger due to electric shock!

Remove the power plug before carrying out

electrical work on the controller!

Plug the power plug of the controller back

in to a socket only after completing all

installation works. In this way, you can pre-

vent the motors from starting up acciden-

tally.

NOTICE!

To avoid damage to the system, the installation

location must be dry, capable of carrying the

load and frost-free.

If the fresh water station is not installed directly on

the storage tank, note the following points:

1.

Determine the installation location of the

fresh water module near to the buffer tank.

On the heating side, the pipes must not

exceed a length of 4 m for DN 32.

2.

During installation, you can use a drilling

template as an assembly aid. One can be

found on the station.

3.

Transfer the dimensions for the holes to the

wall.

4.

Bohren Sie die Löcher und stecken Sie die

beiliegenden Dübel hinein.

5.

Drehen Sie die Schrauben so weit in die

Dübel hinein, dass sie noch etwa 40 mm aus

der Wand heraus stehen.

6.

Remove the station from the packaging.

7.

Remove the front insulation jacket.

13