Fig. 4: Distance between the holes

8.

Hang the fresh water module onto the

screws. Tighten the screws so that the insu-

lation on the sides is flush to the wall.

9.

Connect the pipes of the fresh water module

to the system in accordance with Fig. 5.

1. Primary side:

Return flow to buffer tank,

Connection 1/2" OT,

Piping at least DN 25, 28 x 1,5 mm,

Maximum length 2 m

2. Secondary side:

Hot water circulation, return,

Connection 1" OT, flat-sealing

3. Secondary side:

Cold water inlet,

Connection 1" OT, flat-sealing

4. Secondary side:

Hot water outlet,

Connection 1" OT, flat-sealing

5. Primary side:

Inlet from buffer tank,

Connection 1 1/2 OT,

Piping at least DN 25, 28 x 1,5 mm,

Maximum length 2 m

A

B

1

2

3

5

4

Fig. 5: Piping of the fresh water station

A: Pipe distance from the wall

(secondary) = 167 mm

B: Pipe distance from the wall (primary) = 95 mm