Cleaning the jar filter, Cleaning vacuum pump filters – Rena XPS-ProFeed Shuttle User Manual

Page 20

Advertising
background image

-

14

-

Cleaning the Jar Filter

This Jar Filter is used to remove dust and debris from the air intake
before it reaches the vacuum pump.

Location: Mounted on tubing that connects to vacuum pump.
Located in the base of the Shuttle Feeder.

WARNING!

JAR IS GLASS. TAKE PROPER PRECAUTIONS TO GUARD
AGAINST FRAGMENTING OR BREAKING THE GLASS.

CAUTION

GLASS JAR CAN EXPLODE IF SUBJECTED TO MORE THAN
5 PSI (0.35 BAR).


Cleaning: It is recommended that the Jar and Filter (felt) be cleaned after every 100 hours of
operation. Unscrew and remove any debris from within the Jar. Use a compressed air hose to
clean the felt Filter. Then re-install the Jar.

Cleaning Vacuum Pump Filters

Vacuum Shuttle Feeder is equipped with an
Oilless Vacuum Pump. It does not require
lubrication, however it does require cleaning.

Remove the two Filter Assemblies in the
front of the Pump and brush the Filters with
a stiff brush regularly.

WARNING!

CHECK VACUUM PUMP AT LEAST
ONCE A MONTH. FAILURE TO DO SO
CAN AFFECT PERFORMANCE OR
EVEN CAUSE PUMP OVERHEATING
AND FAILURE.

CAUTION

THE VACUUM PUMP IN THE SHUTTLE
FEEDER IS AN OILLESS PUMP.
DO NOT ATTEMPT TO PUT OIL OF
ANY KIND IN THE PUMP!

Advertising