Call for heat ends and the heater shut

s of

f?

Y

es

No

Troubleshooting ends.

Thermost

at is not

working properly

.

Replace it if necessary

.

Is the green light still on?

Y

es

No

T

urn of

f gas &

electricity immediately

.

Replace the gas valve.

Remove valve lead at ignition module. Does valve close?

No

Y

es

Recheck thermost

at

and wiring.

T

roubleshooting

continued from the previous p

age.

T

roubleshooting

continued from the previous p

age.

Check the sp

ark gap.

Is it 3/16”?

No

Y

es

Adjust the sp

ark gap

to 3/16”.

Has all the air been purged from the gas supply lines?

No

Y

es

Purge the gas supply line.

Check the inlet pressure to the gas valve. Is it between minimum and maximum for the gas type?

No

Y

es

Adjust supply gas pressure. Rest

art

troubleshooting.

Check the manifold gas pressure during st

artup. Is it zero

inches?

Y

es

No

Replace gas valve.

Af

ter an initial step

opening, is the manifold gas pressure correct?

No

Y

es

Adjust manifold gas pressure. Rest

art

troubleshooting.

Call factory for assist

ance.

Check orifice and holder for blockage (i.e. spider web). Is there any blockage?

Y

es

No

Clear blockage.