Space Ray RSTP Series User Manual

Page 38

Advertising
background image

Form 43206000
Sept 2011

-37-

CONTROL COMPONENTS

CONTROL COMPONENTS

CONTROL COMPONENTS

CONTROL COMPONENTS

Item No.

Item No.

Item No.

Item No.

Part No.

Part No.

Part No.

Part No.

Description

Description

Description

Description

51

30279000

Transformer - 120/24V 20VA 50/60Hz

52

30281000

Terminal Block - #EK-204

Labels / Manual

Labels / Manual

Labels / Manual

Labels / Manual

Item No.

Item No.

Item No.

Item No.

Part No.

Part No.

Part No.

Part No.

Description

Description

Description

Description

Qt

Qt

Qt

Qty.

y.

y.

y.

53

43206000

Installation and Operation Instructions (not shown)

1

54

42360000

Label, Connection Wire Diagram

1

55

42785000

Label, Ladder Wire Diagram

1

56

42309000

Label, Clearance to Combustibles

1

57

42309010

Label, Gas Connector Warning

1

58

42848000

Label, Nameplate

1

59

42013000

Label, “Space-Ray” Logo

1

60

42922040

Label, Side Wall Venting

1

61

42834000

Label, 120V Caution

1

62

42875000

Label, Warning

1

1

2 3

4

5

6

7

8

9

10,11,12

13

14,15

16,17,18

19

20

5

43

44

41

39

40

32

33

35

34

45

22

24

23

26

27

25

28,30,31

29

21

62

52

50

51

46

37

42

49 48

47

36

59

WIRE LEGEND

ENGLISH

FRANCAIS

BK

BLACK

NOIR

W

WHITE

BLANC

R

RED

ROUGE

BL

BLUE

BLEU

G

GREEN

VERT

V

VIOLET

VIOLET

A

AMBER

AMBRE

42706000 Rev. G 1/05

G

BL

BL

BK

BK

R

W

BK

BK

R

BK

W

BK

BK

BK

W

DRAFT

INDUCER

MOTOR

GAS VALVE

AIR SWITCH

25V

(GND)

25V GND

(BURNER)

VALVE VALVE

TRANSFORMER

120V PRIMARY

24V SECONDARY

A

G

R

IGNITION MODULE

HIGH VOLTAGE

CABLE

ELECTRODE

GAP 3/16”

CONTINUE TO

ADDITIONAL

HEATERS

NEUTRAL

120V

THERMOST

A

T

GROUND

L1

L2

TERMINAL

BLOCK

FACTORY WIRING

FIELD WIRING

CONNECTION WIRING DIAGRAM

CONTROL CABINET

If any of the original wire as supplied

with the appliance must be replaced.

It must be replaced with wiring material

having a temperature rating of at least

105oC. (18 AWG. - UL / CSA 600V

Type TEW)

When connecting the supply circuit to

the heater, wiring material having a

minimum size of 14 AWG and a

temperature rating of at least 90oC

shall be used.

MONITORING LIGHTS

Schéma de circuit de connexion

Circuit d'origine

Connexions client

Lampes témoins

Neutre

Terre

Vers les autres

radiateurs

Plaque à

bornes

Transformateur

bobine primaire 120ÊV

bobine secondaire 24ÊV

pressostat

Robinet à gaz

Écartement

d'électrode

4,7Êmm

Haute tension

Armoire de commande

Bloc d'allumage

Moteur

d'amorce

d'aspiration

S'il faut remplacer un fil de l'appareil

d'origine, utiliser exclusivement des fils

à température de service nominale

d'au moins 105C (18 AWG. - UL / CSA

600ÊV

Type TEW).

Pour raccorder le circuit d'alimentation

au radiateur, utiliser des fils de calibre

14 AWG ou plus à température de

service nominale d'au moins 90C.

SCHEMATIC WIRING DIAGRAM

MOT

Motor

Moteur

GL

Green Light Témoin vert

TRANS 24V Transformer Transformateur 24ÊV

RL

Red Light Témoin rouge

AS

Air Switch pressostat

SM

Ignition Module Bloc d'allumage

IG/S

Ignitor / Sensor électrode

V

Gas Valve Robinet à gaz

AL

Amber Light Témoin ambre

MOT

120V

GL

TRANS

RL

AS

IG/S

AL

V

SM

42785000 Rev. C 10/04

25V GND

25V

54

55

60

57

Alternate Supply

Locations

TYPICAL GAS

CONNECTION

END VIEW

Movement

14 - 17”

(356 - 432mm)

Control Box

SIDE VIEW

Flexible Connector

Optional Second Stage Regulator with

Vent Leak Limiter if required to reduce

the Supply Pressure below 14” W.C.

Recommended Gas

Pressure 2 PSIG

Gas Supply

Piping

Sediment Trap

(Drip Leg)

43344050 Rev. C 3/09

Install the gas flexible hose as shown in the diagram below:
Sharp bends, kinks, twists and tension in the hose may cause failure resulting in a gas

leak.
Failure to follow these instructions may result in death, serious injury or property damage.

Note: When venting a single

heater horizontally through a

combustible outside wall the

vent must pass through a 2”

clearance thimble (Air Jet No.

4VT or Ameri-vent No 4EWT

for the 40 – 75,000 BTU

heaters and Air-Jet No 6VT or

Ameri-Vent No. 6EWT for the

80 – 250,000 Btu heaters) or

other thimbles which are listed

by nationally recognized testing

agency.

Attach a vent cap (Breidert No.

4L or equivalent for the 40-

75,000 BTU heaters or Breidert

No. 6L or equivalent for 80 –

250,000 BTU heaters) to the

end of the pipe.

Minimum equivalent length of

vent pipe = 5ft (1.5m)

Maximum equivalent length of

vent pipe = 75ft (23m)

THIS UNIT EQUIPPED WITH A

2 AMP IN LINE-FUSE FOR

OVERCURRENT PROTECTION

OF CONTROL CIRCUIT

ELECTRIC SHOCK

HAZARD

Disconnect electrical supply

before servicing
Failure to follow these

instructions may result in

death, serious injury or

property damage.

WARNING

DRAFT INDUCER SERIAL NUMBER

42922020 Rev C 8/05

SIDEWALL VENTING ONLY

UN MUR LATÉRAL A É R AT I O N

ELECTRICAL SHOCK

HAZARD

DISCONNECT POWER

BEFORE OPENING COVER

CAUTION

120 VOLTS

42834000

61

WARNING: Improper

installation, adjustment,

alteration, service or

maintenance can cause

property damage, injury

or death. Read the

Installation, Operating

and Maintenance

Instruction thoroughly

before servicing this

equipment.

AVERTISSEMENT: Une

installation, un réglage, une

modification, une réparation

ou un entretien incorrect peut

entraîner des dommages

matérials, des blessures ou

la mort. Lisez attentivement

les instructions d’installation,

de fonctionnement et

d’entretien avant de procéder

à l’installation ou à l’entretien

de cet équipment.

WARNING: If not

installed, operated and

maintained in accordance

with the manufacturer’s

instructions, this product

could expose you to

substances in fuel or from

fuel combustion which can

cause death or serious

illness and which are

known to the State of

California to cause cancer,

birth defects or other

reproductive harm.

WARNING: This product

contains a chemical known

to the state of California to

cause cancer.

This heater can be

installed in various

configurations as shown

in the heater layout

section of the instructions

42875000 Rev. E 10/04

38

58

56

Combustible material must be located outside the clearance dimensions listed.

Ceiling Clearance is 12” (30cm) when installed in an UNVENTED configuration. Ceiling

clearance is 18” (46cm) when the optional corner reflectors are not used on ETS or LTS.

Failure to do so may result in death, serious injury or property damage

Models LTS/LTU/ETS/ETU

43344000 Rev. B 10/04

Le dégagement au-dessus de l'appareil doit être d'au moins 30 cm quand l'appareil est installé

SANS ÉCHAPPEMENT.

Le dégagement au-dessus de l'appareil doit être d'au moins 46cm

quand les réflecteurs d'angle optionnels ne sont pas utilisés sur l'ETS ou le LTS.

D

D

Dessous, 6m du brûleur

Below 20ft from burne

r

C*

20ft (6m)

Model No

A

B

C

D

E

F

C*

40,50

27”

40”

30”

48”

12”

-

(69cm)

(15cm)

(104cm)

(76cm)

(122cm)

(30cm)

60,75

27”

60”

30”

48”

12”

-

(69cm)

(15cm)

(145cm)

(76cm)

(122cm)

(30cm)

80,90

52”

84”

30”

52”

12”

72”

(132cm)

(15cm)

(145cm)

(76cm)

(122cm)

(30cm)

(183cm)

100

66”

88”

40”

66”

20”

72”

(168cm)

(15cm)

(224cm)

(102cm)

(168cm)

(30cm)

(183cm)

110,120,

66”

101”

40”

66”

20”

72”

125,130

(168cm)

(15cm)

(257cm)

(102cm)

(168cm)

(51cm)

(183cm)

140,150,

84”

106”

48”

84”

24”

72”

160,175

(213cm)

(15cm)

(269cm)

(122cm)

(213cm)

(61cm)

(183cm)

180,200,

84”

18”

132”

48”

84”

24”

72”

225,250

(213cm)

(46cm)

(335cm)

(122cm)

(213cm)

(61cm)

(183cm)

Horizontal

B

C

A

A

45 degrees

B

C

E

F

Montage horizontal

Montage à 45°

GAS TYPE

SUPPLY PRESSURE
Pression de Sortie

Type de Gaz

MAXIMUM

MINIMUM

MANIFOLD PRESSURE
Pression a l’echappement

INPUT Btu/Hr

Consommation Btu / Hr

ORIFICE SIZE

Dimensions bec Veilleuse

MODEL NO.
No. de Modelè

Installation in:

1. Aircraft hangars must be in accordance with the standard for Aircraft Hangars.

ANSI/NFPA 409 (latest edition).

2. Public garages must be in accordance with the standard for parking structures,

ANSI/NFPA 88a (latest edition), or with the standard for repair garages,

ANSI/NFPA 88b (latest edition)

SERIAL NO.
No. de Série

LIGHTING & SHUTDOWN INSTRUCTIONS
1. Turn on gas & electrical supply.

2. Set thermostat to call for heat.

3. Ignition should occur after prepurge.

4. If ignition fails, the unit will spark for approximately 21 seconds

& go into safety lockout. Turn thermostat (or power) off for 60

seconds to take out of lockout.

5. If heater does not light, shut off gas completely for 5 minutes

before attempting to relight.

6. To shut down the heater, turn off the gas & electrical supply.

Infrared Radiant Tube Heater

Radiateur à tuve rayonnant à infrarouge

Gas Fired products Inc. Charlotte, NC

INSTRUCTIONS D’ALLUMAGE ET DE FERMETURE
1. mettre la valve a gaz et l’interrupteur a “ON”.

2. Creer une demande de chauffage au thermostat.

3. L’allumage devrait se produire apres de prepurge.

4. Si l’allumage ne se fait pas, le controle d’allumage continu de

produire des etincelles sur une periode de 21 sec. et ensuite

tomber en securite. Mettre le thermostat (ou le courant) en

position d’arret (OFF) pour une periode de 60 sec. a fin

d’interrompre le processus de securite.

5. Si l’appareil ne s’allume pas, fermez le gaz completement pour

une period de 5 min. avant d’effectuer une nouvelle tentative

d’allumage.

6. Pour fermer l’appareil, fermez le gaz et le courant electrique.

For indoor installation only

Installer à l’intérieur seulement
Vented or Unvented

ELECTRICAL:

ALTITUDE

ANSI Z83.20 / CSA 2.34 - 2008

Tel: 1800 438 4936 e-mail [email protected]

CODE DATE

42848000 Rev. K 1/09

MAX ANGLE:

Max Angle

Electrique

Advertising