This screen will display the temperature set point for the HP2000, and it will allow the user to
modify the temperature set point for the HP2000. The HP2000 is pre-configured prior to
shipment with a temperature set point of 1500°F. Note: To maximize the accuracy and longevity
of the HP2000, it is recommended that the unit be operated at 1500°F
. To change the
temperature set point, press the up arrow key, ↑. The rightmost character will begin blinking.
Pressing the up arrow key again or pressing the left arrow key, ←, will reset the set point to zero.
Pressing the up arrow key again will increment the number by 1. Example – The following
example will show how to set the temperature set point to 1500. Press the up arrow key once so
that the number 1 is displayed. Press the left arrow key once. The number 10 will now be
displayed with the rightmost number blinking. Press the up arrow key five times so that the
number 15 is displayed. Press the left arrow key twice so that the number 1500 is displayed.
Press the ENT button to set the set point. Pressing the CLR button at any time will return the
user to the first screen without entering any changes. Pressing the Next button will display the
next screen, Alarm Set Point. Pressing the Prev button will display the previous screen, Oxygen
(in ppm), Probe mV and Probe Temperature
.

Screen 4: Alarm Set Point

This screen will display the alarm set point and it will allow the user to modify the alarm
setpoint. The alarm setpoint will act as an overtemp alarm, and if this value is reached, the
HP2000 will decrease the amount of heat being generated to a point below the alarm setpoint.
Example – The following example will change the alarm set point to 1700. Press the up arrow
key once so that the rightmost digit is blinking. Press the up arrow key once so that a 1 is
displayed. Press the left arrow key once so that a 10 is displayed. Press the up arrow key seven
times so that a 17 is displayed. Press the left arrow key twice so that a 1700 is displayed. Press
the ENT key to set the changes. Pressing the NEXT key will display the next screen,
Temperature Mode. Pressing the PREV key will display the previous screen, Temperature Set
Point
.

Screen 5: Temperature Mode