Hardware Installation

This chapter provides detailed information for AS2000 hardware
installation. This chapter includes procedures, required tools and
supplies, and general information for component configuration.
Refer to the shelf planning worksheet when installing the system
components.

Required Hardware and Tools

To install Access System 2000 components, the following tools and
hardware are recommended:

Cross-tip screwdriver for securing shelves to equipment racks

Small adjustable crescent wrench (adjustable spanner)

Small straight–slot screwdriver for setting the address switch

Anti-static wrist strap

Digital voltmeter for testing system power

Network interface and equipment cables

Conduit fittings and bushings for Multi-line Shelf (optional)

Fuse panel and fuses

12-through 22-gauge wire (for DC power and alarm wiring)

Equipment Inspection

WARNING

AS2000 system components contain electrostatic-sensitive circuits.

Before handling components, wear an anti-static wrist strap connected to

frame ground to prevent shock to yourself or damage to circuits from

electrostatic discharge.

Unpack and inspect the following AS2000 components for possible
damage:

Shelves

Fan shelves and heat baffles

Protection switches

Power supplies