Verilink AS2000: The Basics (880-502981-001) Product Manual User Manual

Page 79

Advertising
background image

Monitoring and Troubleshooting

Verilink Access System 2000: The Basics

5-13

Bit Error Rate Alarm Second (BERS)

This is a count of each second during which a network BER alarm
condition existed.

Loss of Frame Second (LOFS)

An LOFS is a count of each second in which the application module
was in a LOF state.

Out of Frame Second (OOFS)

An OOFS is a second experiencing one or more OOF events.

Equipment Low-Density Second (DTED)

This is a second during which a low-density state occurs and the
application module stuffs a one into the signal from the equipment
to maintain minimum ones-density on the DS1 network. The
application module also records a DTED whenever it applies a keep-
alive signal to the network.

Equipment Bit Error Rate Alarm Second (DBER)

This is a second during which the incoming bit error rate from the
equipment exceeds the operator-defined threshold.

Equipment Errored Second

This is the same as the ES previously described, except that it is
detected on the incoming signal from the DS1 equipment.

Equipment UAS, ES-L, and OOFS

These are the same as the UAS, ES-L, and OOFS previously
described, except that they are detected on the incoming signal
from the DS1 equipment.

Table 5-5

Alarms and Performance Report Acronyms in Alphabetical Order

Acronym

T1

E1

Definition

Performance/

Alarm/Event/Flag

Class

AIS

All Ones Indication Signal Received (Red

Alarm)

Alarm

Major

AIS-Receiving

Receiving All Ones Indication Signal (Red

Alarm)

Alarm

Major

AIS-Sending

Sending All Ones Indication Signal (Red

Alarm)

Alarm

Minor

Advertising