Unit configuration, Dsu mp port connections, Unit configuration dsu mp port connections – Verilink PRISM 3060-10 (34-00252.4) Product Manual User Manual

Page 15

Advertising
background image

Unit Configuration

7

Unit
Configuration

Configuration is performed using one of the following methods:

The front panel LCD interface (see Chapter 3 of this manual).

A terminal connected to the SUPV or the NMS port (see Chapter 4 of this
manual).

The 3060 -10 provides non -volatile memory retention of unit configuration in the
event of power failure. This feature allows the unit to automatically restore normal
service following a power loss. Note, however, that when the unit is stored without
power for an extended period, the battery may drain and some parameters may
become corrupted.

Therefore, when the unit is first received for installation or if power has not been
applied for an extended period of time, a factory-default maintenance reset
operation should be performed on the unit. Refer to the procedures detailed in
Maintenance Reset on page 16.

FCC rules require that interconnecting cables carrying high-speed data be shielded
appropriately to minimize radio frequency interference.

DSU MP Port
Connections

The DSU MP physical interface is two standard D-subminiature, 120 -pin female
connectors (Figure 2-2) that break out with two of the cable assemblies
(Figure 2-3). The pinout assignments are shown in Table 2-1.