DSU MP Configuration

25

TDM (Port 1A, 1B, 2A, 2B, 3A, 3B, 4A, 4B, 5A, 5B, 6A, and 6B)

In TDM mode, both DTE interfaces are active and are multiplexed together into
the single DDS network path as shown in Figure 3-11. It allows access to
configuration submenus specific to DTE interface B.

Port

Type

For ports A and B, the Port Type field displays the installed DTE interface:
RS-232C, V.35, or EIA-530.

For port B, the interface is RS-232 only.

Port

Transmit

Clock

Used to select the clock that the unit uses to sample the data transmitted from the
DTE. When set to

INTERNAL

, the data is sampled directly with the transmit data

clock that is also supplied to the DTE as Transmit Clock. The

EXTERNAL

option

uses the external clock supplied by the DTE.

V.54 Loop

Selecting Enable allows the unit to respond to in-band V.54 loop commands. If
Disable is selected, the unit ignores these commands.

CTS Control

and DSR Control

Setting these fields to FORCE TRUE or FORCE FALSE (in DSR mode only)
forces the port control lead output state. INTERNAL allows for normal operation.

DCD Control

Setting this field to FORCE TRUE forces the port control lead output state.
INTERNAL allows for normal operation. Far RTS is similar to INTERNAL except
that in far-end units the RTS lead becomes an additional qualifier. This selection is
only available when in TXP-I or TXP-II mode. When using the Far RTS feature,
ensure that units at both ends are configured for Far RTS. If the unit at the far end
is a 41TDM, its RTS parameter must be set to Normal; if it is set to Force On, Far
RTS does not work.

RTS Control

Request To Send is an input to the unit from the DTE. Clear To Send is an output
from the unit to the DTE. The behavior of RTS and CTS is set as follows. In the
External setting, the unit reacts to RTS from the DTE. When RTS is on, the unit
transmits data normally and turns CTS on. When RTS is off, the unit transmits idle
code to the network and turns CTS off. In the Force True setting, the unit ignores the
state of the RTS lead from the DTE and forces it on internally and forces CTS on.

Alarm on

DTR Loss

Selecting Enable allows the unit to go into alarm on loss of DTR. The default
setting is Disable.