Configuration Screens

55

Alarm

Parameters

The Alarm Parameters screen (Figure 4-13) allows the user to review and set alarm
related thresholds for the selected element. These thresholds are the minimum
acceptable performance levels. To modify the parameters, highlight the desired
statistic, type in the new value (any number from 0 to 900) and press Enter. If this
value is later surpassed, an alarm indication appears. A field set to 0 causes the
element not to alarm on that statistic.

If alarm thresholds are edited from the front panel, the corresponding values are not
reflected on this screen until it is exited and then reentered.

Errored Seconds

A one-second period in which at least one logic error occurred.

Severely Errored Seconds

A one-second period in which at least 320 CRC errors or 1 OOF (out-of-frame)
occurred.

Loss of Signal Seconds

A one-second period in which the T1 received signal is interrupted.

Unavailable Seconds

A one-second period in which consecutive severely errored seconds cause an
unavailable state.

Remote Alarm Seconds

Generated by the terminal equipment when an improper signal is received from the
facility (or after receiving unframed all ones).

3060 DSU x.xx/x.xx

PRISM 3060

Date: MM/DD/YY

No Far End Response

TXPORT Prism 3060-10

Time: HH:MM:SS

----------------------------- ALARM CONFIGURATION -----------------------------

Element: [NEAR]

Errored Seconds (ES): ( 45) Remote Alarm Seconds (RAS): ( 0)

Severely Errored Seconds (SES): ( 5) AIS Seconds (AISS): ( 0)

Loss of Signal Seconds (LOSS): ( 5) Out of Frame Seconds (OOFS): ( 5)

Unavailable Seconds (UAS): ( 0) BPV Seconds (BPVS): ( 0)

( 0) Alarm Reset Timer (seconds): ( 30)

Figure 4-13 Alarm Configuration Screen