Alarm

No

Description

Indication

Actions

6

Capping cycle is

not completed

A/R and
CAP buttons are
flashing

There are a couple of situations, where this
alarm will be initiated:

-

The capping head is obstructed during
the downwards movement: The capping
head is returned to top position. If the
bottle is in the correct position and
nothing seems to obstruct the downwards
movement, the machine has to be
opened to investigate sensors and/or
mechanical faults.

-

The alarm is initiated after the capping is
finished: This could indicate to low air-
pressure. If this not the case then the
machine has to be opened to investigate
sensors and/or mechanical faults.

-

Lack of air pressure

Press the RESET button to reset the alarm and
START button to continue production.

7

Cap station (top-

sensor) not in top
during star wheel
movement.

A/R, START and
CAP buttons are
flashing

Check air pressure, open machine to check
Press RESET button the reset the alarm.

8

Adjust cycle is not

completed

A/R and
ADJUST buttons
are flashing

See the alarm description on alarm number 6 as
the courses of the alarm are the same.
Press RESET button the reset the alarm.

9

N/A

N/A

N/A

10

Round table fault

A/R,
START and
FILL buttons are
flashing

Fault inside machine the round table toothed
wheel is not turning; fault must be investigated
inside machine: Check toothed belt, fuses and
motor.

Advertising