Speed filter type 0 (no filter) – Airmar NMEA 2000® Depth, Датчики User Manual

Page 32

Advertising
background image

DST200 User Manual revision 1.000

Proprietary and Confidential

30

Speed Filter Type 0 (No Filter)

For Speed Filter Type 0, the fields in PGN 126720-43 starting with field 5 are described below.

Field

#

Name

Request

Param. DD

DF

Type Resolution

Value

Remark

5 Filter type

Yes

N/A DF52 4 bits

1

0 = no filter

See remark for field 5 on page 28.

6 Reserved

No

DD001 DF52 4 bits

1

0xF

All bits set to logic “1”

7 Sample interval

No

N/A DF66 uint16

0.01 s 0 to 655.32 seconds

0 = reserved

0xFFFE = restore default

0xFFFF = data not available

/ do not change

Interval of time between successive samples

of the paddlewheel pulse accumulator.
This field is stored in EEPROM and may be

changed with the Command Group Function

PGN 126208. The default value for filter type

0 is 1.00 seconds.


Speed Filter Type 0 causes the Speed Water Referenced value in PGN 128259 to be calculated using only the number of paddlewheel pulses accumulated in the most recent

sample interval. No filtering of the data is performed.
To select speed filter type 0 and specify the sample interval, use the Command Group Function PGN 126208, specifying the individual fields in PGN 126720-43 as follows.

PGN 126720

Field Value

1

135 (decimal)

3

4 (decimal)

4

43 (decimal)

5

0 (filter type)

7

Desired sample interval

Advertising