_

NMEA 2000® RECEIVED PARAMETER GROUP

_

PGN

126720

(0x1EF00)

Addressable Multi-Frame Proprietary

Single Frame:

No

Access Level:

See PID variants

Field

#

Name

DD

DF

Type Resolution

Value

Remark

1 Manufacturer Code

DD172 DF52 11 bits

1

135 (decimal)

Manufacturer Code for Airmar

Technology.

2 Reserved bits

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

3 Industry Group

DD168 DF52 3 bits

1

4 (decimal)

Industry Group for "Marine

Industry".

4 Proprietary ID (PID)

DD005 DF53 uint8

1 bit

0 to 252

Identifier specifying how to

interpret the remaining fields in

this parameter group.

5+ (PID-dependent)

DD000 DF00 undef. undefined undefined

The use of the remaining bytes and

the number of CAN frames

required varies according to the

PID (field 4).

Notes

In order for this received PGN to be recognized by the DST, the Manufacturer Code and Industry Group (fields 1 and 3) must match the values shown.
The use of this PGN with the following Proprietary ID's (field 4) is described on the subsequent pages:

1: Master Reset

130: Restore user EEPROM memory to factory defaults