0x1ef00), Proprietary: reset eeprom – Airmar NMEA 2000® Depth, Датчики User Manual

Page 61

Advertising
background image

DST200 User Manual revision 1.000

59

_

NMEA 2000® RECEIVED PARAMETER GROUP

_

PGN

126720-130

(0x1EF00)

Proprietary: Reset EEPROM

Single Frame:

No

Access Level:

1

Field

#

Name

DD

DF

Type Resolution

Value

Remark

1 Manufacturer Code

DD172 DF52 11 bits

1

135 (decimal)

Manufacturer Code for Airmar

Technology.

2 Reserved bits

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

3 Industry Group

DD168 DF52 3 bits

1

4 (decimal)

Industry Group for "Marine

Industry".

4 Proprietary ID (PID)

DD005 DF53 uint8

1 bit

130 (decimal) = Reset EEPROM

Identifier specifying how to

interpret this PGN.

5 Options

N/A DF52 4 bits

1

0x0 = Restore entire user EEPROM

except Unique Number
0x1 = Restore all message Priorities
0x2 = Restore all message Update Rates
0x3 = Restore all message Priorities and

Update Rates
0x4 = Restore user Unique Number
0x4 to 0xE = reserved
0xF = reserved

6 Reserved bits

DD001 DF52 20 bits

1

0xFFFFF

All bits set to logic "1"

Notes

Upon receiving this PGN, the DST will restore part of user EEPROM memory to its factory default state.
The Options field (field 5) specifies whether all of user EEPROM memory (except the user Unique Number) is to be restored (value 0x0), or only a subset of EEPROM memory

is to be restored.
Note that this PGN requires Access Level 1, even when resetting the Unique Number to its factory default value (option 0x4). The proprietary PGN to change the Unique

Number to a value other than the factory default value, which is described in another document, requires Access Level 2.
In order for this received PGN to be recognized by the DST, the Manufacturer Code, Industry Group, and Proprietary ID (fields 1, 3, and 4) must match the values shown.
Although this is a fast-packet message, the version with this PID fits into a single CAN frame.

Advertising