To select speed filter type 1 and change its settings, use the Command Group Function PGN 126208, specifying the individual fields in PGN 126720-43 as follows.

PGN 126720

Field Value

1

135 (decimal)

3

4 (decimal)

4

43 (decimal)

5

1 (filter type)

7

Desired sample interval

8

Desired filter duration

When changing either of the filter parameters (fields 7 and 8), both parameters must be specified in the Command Group Function PGN 126208.