DST200 User Manual revision 1.000

Proprietary and Confidential

33

NMEA 2000® TRANSMITTED PARAMETER GROUP

PGN

126720-44

(0x1EF00)

Proprietary: Temperature Filter

Single Frame:

No

Priority:

7/Y/N

Update Rate:

0/N/N

Destination:

Address

Query Support:

Yes

Access Level:

1

Field

#

Name

Request

Param. DD

DF

Type Resolution

Value

Remark

1 Manufacturer Code

Yes

DD172 DF52 11 bits

1

135 (decimal)

Manufacturer Code for Airmar Technology.

2 Reserved bits

No

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

3 Industry Group

Yes

DD168 DF52 3 bits

1

4 (decimal)

Industry Group for "Marine Industry".

4 Proprietary ID (PID)

Yes

DD005 DF53 uint8

1 bit

44 (decimal)

44 = Temperature Filter

5 Filter type

Yes

N/A DF52 4 bits

1

0 = no filter

1 = basic IIR filter
2 through 14 = reserved

15 = data not available /

do not change

This field is stored in EEPROM and may be

changed with the Command Group Function

PGN 126208. The default value is 1 (basic IIR

filter).
The format and number of remaining fields in

this parameter group (starting with field 7)

depends on the contents of this field.

6 Reserved

No

DD001 DF52 4 bits

1

0xF

All bits set to logic “1”

7+ (Dependent upon filter type)

No

DD000 DF00 undef. undefined undefined

The use of the remaining bytes and the number of

CAN frames required varies according to the

filter type (field 5).