Distance log – Airmar NMEA 2000® Depth, Датчики User Manual

Page 46

Advertising
background image

DST200 User Manual revision 1.000

Proprietary and Confidential

44

NMEA 2000® TRANSMITTED PARAMETER GROUP

PGN

128275

(0x1F513)

Distance Log

Single Frame:

No

Priority:

6/Y/Y

Update Rate:

1000 mS/Y/Y

Destination:

Global

Query Support:

Yes

Access Level:

0

For further information about the NMEA 2000® protocol, including field descriptions refer to the document, NMEA 2000® Standard for Serial-Data

Networking of Marine Electronic Devices available from NMEA.

Notes

DST200

DT200

No

DT200S

D200

No

D200ST



PGN 128275

supported in:

ST200


Special note for models DT200S and D200ST: On power-up, these units will automatically detect the presence or absence of an optional external speed/temperature sensor. If no

external sensor is detected, then PGNs 128259 and 128275 will not be provided. In this case, the Transmitted PGNs Group List PGN 126464 will exclude those PGNs from its list.

To change the Distance Since Last Reset, use the Command Group Function PGN 126208, specifying the individual fields in PGN 128275 as follows.

PGN 128275

Field Value

4

Desired value (usually 0 to reset log)


See also the following transmitted PGNs:

65409

Proprietary: Speed Pulse Count

126720-41

Proprietary: Calibrate Speed

126720-43

Proprietary: Speed Filter

128259

Speed

Advertising