NMEA 2000® TRANSMITTED PARAMETER GROUP

PGN

126998

(0x1F016)

Configuration Information

Single Frame:

No

Priority:

6/Y/N

Update Rate:

0/N/N

Destination:

Global

Query Support:

Yes

Access Level:

0

For further information about the NMEA 2000® protocol, including field descriptions refer to the document, NMEA 2000® Standard for Serial-Data

Networking of Marine Electronic Devices available from NMEA.

Notes

This PGN is transmitted in response to an ISO Request PGN 59904, or to a PGN 126208 Request Group Function message.
The contents of fields 1 and 2 are stored in nonvolatile memory, and may be programmed using the NMEA Command Group Function, PGN 126208.

To change the state of the Installation Description (fields 1 and 2), use the Command Group Function PGN 126208, specifying the individual fields in PGN 126998 as follows.

PGN 126998

Field Value

1

Desired variable length ASCII

string, up to 70 characters

2

Desired variable length ASCII

string, up to 70 characters