Removing the blackdiamond 8806 ac power cord, S into the channel (see, Figure 85 – Extreme Networks BlackDiamond 8800 Series User Manual

Page 130

Advertising
background image

BlackDiamond AC Power Cord Retaining Brackets

BlackDiamond 8800 Series Switches Hardware Installation Guide

130

Figure 85: Routing the Power Cords in the Channel

NOTE

Leave the ESD-preventive wrist strap permanently connected to the switch, so that the strap is always available
when you need to handle ESD-sensitive components.

Removing the BlackDiamond 8806 AC Power Cord Retainer
Channel

To remove the BlackDiamond 8806 AC power cord retainer channel:

1

Attach the ESD-preventive wrist strap to your wrist and connect the metal end to the ground
receptacle on the top-left corner of the switch front panel.

2

Using a #2 Phillips screwdriver, loosen the captive screw located on each end of the AC power cord
retainer channel.

3

Remove the retainer channel from the switch.

NOTE

Leave the ESD-preventive wrist strap permanently connected to the switch, so that the strap is always available
when you need to handle ESD-sensitive components.

From the left, lay first four
power cords into channel bracket

Lay last two power cords
onto others