Rj-45 connector jackets – Extreme Networks BlackDiamond 8800 Series User Manual

Page 64

Advertising
background image

Site Preparation

BlackDiamond 8800 Series Switches Hardware Installation Guide

64

*

Proprietary to Extreme Networks. Connections between two Extreme Networks 1000BASE-LX interfaces that use 10/125 μm
single-mode fiber can use a maximum distance of 10,000 meters.

RJ-45 Connector Jackets

Use RJ-45 cable with connector jackets that are flush with the connector or that have connectors with a
no-snag feature.

Using cable with jackets that are wider than the connectors can cause:

Connectors that are not properly aligned with the port.

Crowded cable installation, which can cause connectors to pop out of the port.

Figure 33

shows examples of connector jacket types that are not recommended, as well as those that are

recommended.

Figure 33: RJ-45 Connector Jacket Types

1000BASE-T

100BASE-TX

10BASE-T

Category 5 and higher UTP cable

Category 5 and higher UTP cable

Category 3 and higher UTP cable

100

100

100

Table 12: Media Types and Maximum Distances (Continued)

Standard

Media Type

Mhz•Km
Rating

Maximum Distance
(Meters)

0.1" = 1mm actual
39.37% : 254%

SPG_001

Not recommended

Better

Best

Advertising