H3C Technologies H3C S12500 Series Switches User Manual

Page 28

Advertising
background image

20

Step Command

Remarks

72.

Set the clock mode.

clock { master | slave }

Optional.
The default is slave.

73.

Set the CRC length.

crc { 16 | 32 }

Optional.
The default is 32 bits.

74.

Set the loopback mode.

loopback { local | remote }

Optional.
Loopback is disabled by default.
Enable it only when special test is
desired.

75.

Configure the overhead bytes.

flag c2 flag-value

flag { j0 | j1 } { sdh | sonet }

flag-value

Optional.

The default is hexadecimal 16

for C2.

By default, SDH framing

applies. In SDH framing, the
defaults are null for both J0 and

J1.

76.

Set the framing format.

frame-format { sdh | sonet }

Optional.
The default is SDH.

77.

Configure scrambling.

scramble

Optional.
Enabled by default.

78.

Specify the link layer protocol. link-protocol { ppp | fr

[ nonstandard | ietf ] | hdlc }

Optional.
The default is PPP.

79.

Set the interface MTU.

mtu size

Optional.
The interface MTU (in bytes) is in

the range of 64 to 10240 and
defaults to 1500.
The maximum MTU you can
configure for a POS interface is

10240 bytes, but the one that
actually takes effect is 9216 bytes.

80.

Set the signal degrade (SD) or
signal fail (SF) alarm threshold

for the interface.

threshold { sd | sf } value

Optional.
The SD alarm threshold defaults to
10e-6. The SF alarm threshold

defaults to 10e-4.

81.

Set the protective action for

alarms on the interface.

alarm-detect { rdi | sd | sf } action
link-down

Optional.
By default, no protective action for
alarms is set on the interface.

82.

Set the rate of the POS
interface.

speed speed-value

Optional.
By default, the rate of a POS
interface on a LSR1DTCP8L1

subcard is 155 Mbps.

83.

Set the statistics polling
interval of the POS interface. flow-interval interval

Optional.
300 seconds by default.

Advertising