3-2 Operation

Rosemount Analytical Inc. A Division of Emerson Process Management

Model NGA 2000 TO2

a. Menu Lines & Softkey Functionality

Menu lines can be selected with the

↑ key

or the

↓ key. The selected line is dis-

played as white lettering on a black back-
ground (reverse text). Menus can contain
four different types of lines:

Menu Line – A line ending with three dots
(…) indicates that it leads to a submenu.
The submenu can be activated by press-
ing the

↵ key or the → key when the line

is highlighted.

Function Line – A line ending with an
exclamation point (!) indicates that it will
start a function. The function can be acti-
vated by pressing the

↵ key or the → key

when the line is highlighted.

Variable Line – A line ending with a colon
(:) indicates that it displays a module
variable parameter. Some parameters
can be changed and some parameters
display only a status and cannot be
changed. Paramters that cannot be
changed will be displayed below a line
within the menu.

Text Line – A line without punctuation
marks displays information.

Tag Line – At the top of each menu
screen is the tag line of the current chan-
nel. To the right of the Tag is the value of
the indicated channel.

The Function Keys (Softkeys) can some-
times be assigned as Functions (excla-
mation point) or Submenus (three dots)
as shown in Figure 3-2.

Figure 3-2. The Display Screen

b. Common Function Keys

The function keys are shown in Figure 3-1
And Figure 3-2.

Display – Change from the single com-
ponent display to the multi-component
display. F1 in the single component dis-
play.

Measure – Change from menus and
submenus to the single component dis-
play of the selected channel. F1.

Status – Change to the menu “Current
measurement parameters” which displays
the most important parameters and infor-

mation about the status of the current
channel or module. F2 if available. (See
Section 3-4 )

Main – Change from single component
display to the main menu. F3 in the single
component display. (See Section 3-2e)

HOME – Change for various menus to the
main menu. F1.

Channel – Scrolls through the channels
in the same menu. In the main menu and
the single component display menu it
moves between the channels of the con-
nected Analyzers and Analyzer modules.
In the submenus it moves only between

CLD

7.50 ppm

Measure

Status…

Channel

Lock…

MFG Data

-- Main Menu --

Analyzer basic controls (calibration) & setup…

Analyzer and I/O, expert controls & setup…

System configuration and diagnostics…

Display controls…

Time & Date:
System tag:

Menu Line

Function Lines

Variable Lines

Tag Line

Lines below this separator
are information and cannot
be changed.

Function Keys F1 – F5 Legend

Selected Line
(Reverse Text)