Grass Valley KMV-3901 Quick Start v.7.80 User Manual

Page 18

Advertising
background image

12

Setting Up Your KMV-3901/3911 Multiviewer

Networking Setup

The card restarts. The startup sequence takes approximately five minutes, during which
time the Status LED is blinking orange. Once the startup has completed, the Status LED
should be red (steady) because the card is not connected to the network yet.

11 Connect the KMV-3901/3911 card to your Ethernet switch (see

Cabling Diagram

, on

page 8).

12 Check the card’s Status LED again, and make sure that it does not indicate an error

condition (see table below).

If the Status LED indicates an error condition, refer to your multiviewer’s Guide to
Installation and Operation to find out what the other LEDs might be indicating.

13 Verify that the new IP address is effective, by referring to

Finding the System IP Address

and Application Version

, on page 13.

At this point, it is recommended to back up the new configuration to the controller’s
non-volatile memory by saving a restore point.

14 On the Densité frame’s local control panel, press the CONTROLLER button.

15 Press the [–] button repeatedly until RESTORE POINTS appears on the display, and then

press the SEL button.

16 Press the [–] button repeatedly until SAVE A CARD appears on the display, and then

press the SEL button.

Green

Blinking orange

Red

Blinking red

Normal

Booting (or the card is
selected for local control)

No Ethernet / SD card
error

Fan failure / no rear /
duplicate IP address

Select button

Status LED

Boot LED,
Power LED,
CPU Status LED (other side of board)

SDI LEDs

USB connector (other side of board)