Kayak HD — Installation and Service Manual

Section 2 — Installation

Internal Redundant Power Supply Option

This option provides redundant power for the Kayak HD video processor
chassis and control panel. It slides into an extra power supply slot in the
video processor chassis.

Figure 23. KHD-PSU Internal Redundant Power Supply Option

Removing and Replacing the Kayak HD Frame Door

WARNING

Be very careful when opening the Kayak HD frame door. Take precautions
to avoid electrical shock from components by following the safety precau-
tions described in detail in

Warnings on page 18

and in

Cautions on

page 19

. In particular you want to avoid the possibility of electrical shock

by powering down the system and unplugging all equipment before
working on internal components. In addition you should wear a grounding
strap to prevent electrical damage to sensitive electronic components.

CAUTION Operate only with covers and enclosure panels in place — Do not operate

this product when covers or enclosure panels are removed.

You need to take care not to damage the door by following the procedures
described below.

Note

A minimum vertical clearance of 7.62 mm (0.3-in.) above the Kayak HD 4 RU
Compact frame door is required to remove the door. When installing the
Kayak HD 4 RU Compact frame in the rack, take care to leave room for
removal of the front door. The front door lifts off vertically and must have suf-
ficient clearance room in order to remove it. If you have equipment mounted
too close to the Kayak HD 4 RU Compact Frame, you may not be able to
remove the door.