Server error messages 12200 - 12299 – Sybase 11.9.x-12.5 User Manual

Page 506

Advertising
background image

Server Error Messages 12200 - 12299

1180

Server Error Messages 12200 - 12299

Number

Severity

Text and Explanation

12201

20

Lock found in lock cache not on global lock chain: dbid %d, objid %d, locktype %d,
sufficiency class %d

Explanation:

Adaptive Server encountered an internal error affecting the current

process. Reconnect to Adaptive Server. Report the error to your System Administrator so
dbcc diagnostics can be run.

12202

10

Could not initiate lock wait checking because Adaptive Server has run out of alarms. If
your application uses this feature, try rebooting the server.

Explanation:

This is an informational message. Unless otherwise specified, no action is

required. Contact your System Administrator about any warning issued in the message.

12203

18

Lock cache entry not found for spid %d, lock 0x%lx, type %d, suff class %d. Please notify
your system administrator.

Explanation:

Command failed due to internal Adaptive Server problem. Perform any

diagnostic action indicated by the message. Report the error to your System
Administrator.

12204

18

Attempted to redo deadlock search as a result of a lock upgrade. Found too many
SH_NKL lockrecs. Please contact Sybase Technical Support.

Explanation:

Command failed due to internal Adaptive Server problem. Perform any

diagnostic action indicated by the message. Report the error to your System
Administrator.

12205

17

Could not acquire a lock within the specified wait period. %s level wait period=%d
seconds, spid=%d, lock type=%s, dbid=%d, objid=%ld, pageno=%ld, rowno=%ld.
Aborting the transaction.

Explanation:

Command failed due to resource limitation. Modify the command to fit

available resources, retry when the resource is available, or contact your System
Administrator to address the resource problem.

12206

20

Internal Error in lock manager routine: Attempted lock anti-inheritance when the parents
sdes chain does not include the dbid and objid corresponding to the child thread which are
dbid=%d and objid=%d.

Explanation:

Adaptive Server encountered an internal error affecting the current

process. Reconnect to Adaptive Server. Report the error to your System Administrator so
dbcc diagnostics can be run.

12207

10

Could not acquire a lock within the specified wait period. %s level wait period=%d
seconds, spid=%d, lock type=%s, dbid=%d, objid=%ld, pageno=%ld, rowno=%ld.

Explanation:

This is an informational message. Unless otherwise specified, no action is

required. Contact your System Administrator about any warning issued in the message.

Advertising