Non-Default Settings for Switch SW1

Your particular situation may demands setting switches to different values than
the defaults.

The Bus Address may be set from 00 to 1F hexadecimal (0 to 31 decimal) using
SW1, Positions 1-5.

Positions 1-5 = Node Address (Position 1 = LSB or 1's digit, Position 5 = MSB
or 16's digit)

0 = Off 1 = On

SW1 Optional Settings – Positions 1-5

Value

Position

Value

Position

1

2

3

4

5

1

2

3

4

5

SBA=0

1

1

1

1

1

SBA=16

1

1

1

1

0

SBA=1

0

1

1

1

1

SBA=17

0

1

1

1

0

SBA=2

1

0

1

1

1

SBA=18

1

0

1

1

0

SBA=3

0

0

1

1

1

SBA=19

0

0

1

1

0

SBA=4

1

1

0

1

1

SBA=20

1

1

0

1

0

SBA=5

0

1

0

1

1

SBA=21

0

1

0

1

0

SBA=6

1

0

0

1

1

SBA=22

1

0

0

1

0

SBA=7

0

0

0

1

1

SBA=23

0

0

0

1

0

SBA=8

1

1

1

0

1

SBA=24

1

1

1

0

0

SBA=9

0

1

1

0

1

SBA=25

0

1

1

0

0

SBA=10

1

0

1

0

1

SBA=26

1

0

1

0

0

SBA=11

0

0

1

0

1

SBA=27

0

0

1

0

0

SBA=12

1

1

0

0

1

SBA=28

1

1

0

0

0

SBA=13

0

1

0

0

1

SBA=29

0

1

0

0

0

SBA=14

1

0

0

0

1

SBA=30

1

0

0

0

0

SBA=15

0

0

0

0

1

SBA=31

0

0

0

0

0

The Smart Trac Genius card can be set to communicate at four different baud
rates: 153.6 Standard, 153.6K Extended, 38.4K and 76.8K. Use SW1, positions
6 and 7 to set the baud rate.

0 = Off 1 = On\

SW1 Optional Settings – Positions 6-7 (serial bus baud rate)

Baud Rate

Position 6

Position 7

153.6K Std (default)

0

0

76.8K

1

0

38.4

0

1

153.6K Extended

1

1

Serial Bus Address

Serial Bus Baud Rate