Linkskey LKV-IOP08 User Manual

Page 14

Advertising
background image

ioPower User guide

Serial Command Set

Rev. 1.41 Copyright© All rights reserved. Feb 2005

11


ON – Power ON
[Description]Power on one/all AC outlet port(s) immediately
[Usage] ON [bank_number] [port_number]
[Examples]
ON 1 4 – Power on port 4 on bank 1 immediately
ON 1 0 – Power on all ports on bank 1 immediately
ON 0 0 – Power on all ports on all cascaded banks immediately
Notes:
1. A port number of 0 represents all ports; while a bank number of 0 represents all
cascaded banks.
2. The command: ON 0 x ………, x = 1~9, is not valid.

OF – Power OFF
[Description]Power off one/all AC outlet port(s) immediately
[Usage] OF [bank_number] [port_number]
[Examples]
OF 1 4 – Power off bank 1 port 4 immediately
OF 1 0 – Power off bank 1 all ports immediately
OF 0 0 – Power off all ports on all cascaded banks immediately
Notes:
1. A port number of 0 represents all ports; while a bank number of 0 represents all
cascaded banks.
2. The command: OF 0 x ………, x = 1~9, is not valid.


TA – Timer

Activate at specific time point

[Description]Set the timer to turn on/off a specific port

at specific time

[Usage] TA [bank_number] [port_number] [ON | OF] [Time_point]
[Examples]

TA 1 4 ON 01:22:50 – Set timer to power on port 4 on bank 1 exactly

at

01:22:50.

TA 1 0 ON 00:10:00 – Set timer to power on all ports on bank 1 exactly

at 00:10:00

TA 0 0 OF 01:00:00 – Set timer to power off all ports on all cascaded

banks at 01:00:00

Notes:
1. A port number of 0 represents all ports; while a bank number of 0 represents all
cascaded banks.
2. The command: TA 0 0x ………, x = 1~9, is not valid.
3. The system time should be calibrated before use for the first time.


T

F – Timer Activate after specific time duration

[Description]Set the timer to turn on/off a specific

port after specific time duration

[Usage] T

F [bank_number] [port_number] [ON | OF] [Time_duration]

[Examples]
TF 1 4 ON 03:25:56 – Set timer to power on port 4 on bank 1 exactly

after 3 hour 25 minutes and 56 seconds.

TF 1 0 ON 00:10:00 – Set timer to power on all ports on bank 1 exactly

after 10 minutes

TF 0 0 OF 01:00:00 – Set timer to power off all ports on all cascaded

banks after 1 hour.

Notes:
1. A port number of 0 represents all ports; while a bank number of 0 represents all
cascaded banks.
2. The command:

TF 0 0x ………, x = 1~9, is not valid.

Advertising