ED – Timer Activate everyday at a specific time point
[Description]Set the timer to turn on/off a specific

port every day at specific time

point
[Usage]

ED [bank_number] [port_number] [ON | OF] [Time_point]

[Examples]

ED 1 4 ON 02:12:20 – Set timer to power on port 4 on bank 1 exactly

every day at 02:12:20.

ED 1 0 ON 00:10:00 – Set timer to power on all ports on bank 1 exactly

every day at 00:10:00.

ED 0 0 OF 01:00:00 – Set timer to power off all ports on all cascaded

banks every day at 01:00:00.

Notes:
1. A port number of 0 represents all ports; while a bank number of 0 represents all
cascaded banks.
2. The command:

ED 0 0x ………, x = 1~9, is not valid.

EW – Timer Activate every week at a specific time point
[Description]Set the timer to turn on/off a specific

port every week at specific time

point
[Usage]

EW [bank_number] [port_number] [ON | OF] [day] [Time_point]

[Examples]

EW 1 4 ON 1 01:22:50 – Set timer to power on port 4 on bank 1 exactly

every Monday at 01:22:50..

EW 1 0 ON 3 00:10:00 – Set timer to power on all ports on bank 1 exactly

every Wednesday at 00:10:00.

EW 0 0 OF 5 01:00:00 – Set timer to power off all ports on all cascaded

banks every Friday at 01:00:00.


Notes:
1. A port number of 0 represents all ports; while a bank number of 0 represents all
cascaded banks.
2. The command:

EW 0 0x ………, x = 1~9, is not valid.

3. A day of 0 represents Sunday; while a day of 1 represents Monday, later calculate
for this reason.


TQ – Timer Quit
[Description]Cancel a specific/all timer setting(s)
[Usage] TQ [bank_number] [port_number] [ON | OF]
[Examples]
TQ 1 4 ON – Cancel timer power-on setting on port 4 of bank 1
TQ 1 4 ON – Cancel timer power-on setting on port 4 of bank 1
TQ 0 4 - Cancel timer power-on&off setting on port 4 of bank 1
TQ 1 0 OF - Cancel timer power-off setting on all port of bank 1
TQ 0 0 ON - Cancel timer power-on setting on all port of all banks
TQ 0 0 - Cancel timer power-on&off setting on all port of all banks

Notes:
1. A port number of 0 represents all ports; while a bank number of 00 represents all
cascaded banks.
2. The command: TQ 0 x ………, x = 1~9, is not valid.
3. If you have not specified either “ON” or “OF” as the command parameter, it is
assumed that this Timer Quit directive will be directed on both the Power-ON and Power-
OFF setting of that specific port.