Installation, 2010 magnum energy, inc – Magnum Energy Series Stacking Cable Kit (ME-SSI) User Manual

Page 17

Advertising
background image

©

2010 Magnum Energy, Inc.

Installation

12

Single In/Single Out (60 Amps) – Using both inputs (HOT 1

and HOT 2) for the input and output provides up to 60 amps AC

pass-thru (30 amps each line). The HOT 1 line passes through

the unit and also shares power with the charger. The HOT 2 line

passes through the unit without sharing power with the charger.

Use this confi guration if the output from your AC source provides

more than 30 amps. See Figures 9 and 10 below.

120V

120V

240V

240V

120V

120V

AC

LOADS

(120 /240 )

NEU

L1

L2

GND

AC

SOURCE

( 120 / 240)

NEU

L1

L2

GND

HOT 1 IN

HOT 1 OUT

HOT 2 IN

NEUT IN

NEUT OUT

MS4024 (L1)

HOT 2 OUT

GND

HOT 1 IN

HOT 1 OUT

HOT 2 IN

NEUT IN

NEUT OUT

HOT 2 OUT

GND

MS4024 (L2)

AC

SOURCE

( 120 only )

NEU

HOT

GND

120V

HOT 1 IN

HOT 1 OUT

HOT 2 IN

NEUT IN

NEUT OUT

MS4024 (L1)

HOT 2 OUT

GND

HOT 1 IN

HOT 1 OUT

HOT 2 IN

NEUT IN

NEUT OUT

HOT 2 OUT

GND

MS4024 (L2)

AC

LOADS

( 120 / 240)

NEU

L1

L2

GND

240V

(Invert only)

120V

120V

Info: The dashed lines between the NEUT IN and NEUT

OUT in Figures 7 through 10 represent the RD and MS-

AE Series models. Those models have no internal relay

between the NEUT IN and NEUT OUT, as they are tied

together.

Info: Refer to the MS4024 Owner’s Manual for

information on how to connect the AC terminal.

Figure 9, Single In/Out (60A with 120/240VAC source)

Figure 10, Single In/Out (60A w/ 120VAC source only)

Advertising