Installation – Magnum Energy Series Stacking Cable Kit (ME-SSI) User Manual

Page 9

Advertising
background image

©

2010 Magnum Energy, Inc.

Installation

DC Wiring Using One Battery Cable Pair – Both inverters

share a single battery cable pair (one positive and negative). It is

divided between the two inverters and is protected by a single DC

disconnect/overcurrent device. The positive battery cable is con-

nected to the positive terminal of one inverter and the negative

battery cable is connected to the negative terminal of the other in-

verter. This is to ensure an even charge and discharge through the

batteries. The positive and negative interconnect cables provided

are used to place the inverters as close to each other as possible.

Figure 3, DC Wiring Using One Battery Cable Pair

4

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

6 volt

battery

This diagram is for a 24 VDC

battery system. Ensure your

battery bank is wired correctly .

This battery bank uses two battery strings . They must

be connected together in parallel to provide a single

battery bank to the inverters .

DC Positive and

Negative Interconnects

(from ME-SSI kit)

MS4024

L1

inverter

MS4024

L2

inverter

DC disconnect and

overcurrent

protection

Stacker cable

(from ME-SSI kit)

Advertising