Alarm in/out terminals, 1] alarm input [2] alarm output – Elmo Network Pan-Tilt-Zoom Camera PTC-201CIP User Manual

Page 23

Advertising
background image

- 22 -

7. ALARM IN/OUT TERMINALS

By short-circuiting the ALARM 1 IN or ALARM 2 IN Terminal Block to the GND

terminal on the Terminal Block, the Camera moves to the allocated preset position.

• When short-circuiting the ALARM 1 IN terminal to the GND terminal,

the Camera moves to the preset position 1.

• When short-circuiting the ALARM 2 IN terminal to the GND terminal,

the Camera moves to the preset position 2.

Then, when the time set from the OSD menu has passed, the Camera moves back

automatically to the lastly executed preset position.

Terminal name

1 IN

GND

2 IN

OUT

Function

Inputs the alarm signal <1>.

Grounds.

Inputs the alarm signal <2>.

Outputs the alarm signal.

Signaling

GPI

-

GPI

Open-collector output

• Regarding time setting, refer to the setting in the OSD menu screen.

When the alarm input signal has been activated and the Camera has moved to the specified

position, the alarm signal is outputted at the ALARM OUT terminal for the time preset

from the OSD menu.

Pin arrangement

[1] Alarm input

[2] Alarm output

(1)

Regarding time setting, refer to the setting in the OSD menu screen.

(2)

Signal specification

Max 12V, 30mA (open-collector output)

Advertising