File transfer configurations – Elmo Network Pan-Tilt-Zoom Camera PTC-201CIP User Manual

Page 45

Advertising
background image

- 44 -

Item

Outline

IP address of
image receiving
server

Specifies the IP address of the destination host to save.
Factory set to 0.0.0.0.

Password of
image receiving
server

Specifies the password of the above account.
Not factory set

Specifies which mode is used for file transfer, the passive mode or active mode. When the port
is limited by firewall, etc., use the passive mode. For whether the passive mode should be used
or not, ask the administrator of the network in use.
Factory set to no use.

Passive mode

Specifies the directory to save the image file. Specifies the write-enabled directory of the
assigned account. Not factory set. (The root directory has been specified.)

Directory to
save

Resolution

Specifies the resolution of the image to be saved, from among VGA and QVGA. The
resolution is 640X480 for VGA and 320X240 for QVGA.
Factory set to VGA.

Specifies the name of the file to be saved. Automatically adds the extension [.jpg] to the file
name. Since any file under the same name in the saving destination is overwritten, specify a
different file name from the existing file names.
Factory set to [img].

File name

Specifies whether Yes/No to the addition of sequential number to the file name. When [Yes] is
specified, the image is saved under the file name specified for the image with the sequential
number added (e.g., img000000.jpg img000001.jpg) each time the file is saved. When the
power supply to the Camera is turned ON or the FTP client settings are changed, the
sequential number to be added to the file name is reset to the number specified for the first
number of sequence.
Factory set to Yes.

Add sequential
number to file
name?

First number of
sequence

Specifies the first number of sequence when the sequential number is added to the file name.
Factory set to [0].

Last number of
sequence

Specifies the last number of sequence when the sequential number is added to the file name.
Then, if there is a file already saved with the first number of sequence, that file will be
overwritten when the new file is saved. Therefore, the last number of sequence should
preferably be larger.
Factory set to [999].

Port number of
image receiving
server

Specifies the port number used by the FTP server in operation at the destination host to save.
Normally, no need to be changed.
Factory set to 21.

Account of
image receiving
server

Specifies the account name used for connection to the destination host to save.
Factory set to anonymous.