Installing the Device

3-6

Hardware Installation

3.4.1

Rackmount Installation

To install the device in a 19-inch rack, you need:

Two rackmount brackets and mounting screws (rackmount kit) shipped with the device.

Four user-supplied screws to attach the device to a standard 19-inch rack.

3.4.1.1

Guidelines for Rackmount Installation

The installation site must be within reach of the network cabling and meet the requirements listed
below:

Appropriate grounded power receptacles must be located within seven feet of the location.

An ambient temperature between 5

°C (41°F) and 40°C (104°F) must be maintained at the

installation site with fluctuations of less than 10

°C (18°F) per hour.

3.4.2

Rack Mounting the Device

Proceed as follows to install the device into a 19-inch rack:

1. Attach the rackmount brackets

to the device, as shown in

Figure 3-4

, using the eight

M3 x 10 mm flathead screws

in the rackmount kit.

Figure 3-4

Attaching the Rackmount Brackets

CAUTION: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the device.

WARNING: Before installing the device

into a rack, ensure that the rack can support the

device(s) without compromising the stability of the rack. Otherwise, personal injury
and/or equipment damage may result.

Rackmount brackets

M3 x 10 mm flathead screws

CPU RPS

1

16

17

32

33

48

49

51

2

3

4

5

6

7

8

9

10

1

1

12

13

14

15

18

19

20

21

22

23

24

25

26

27

28

29

30

31

34

35

36

37

38

39

40

41

42

43

44

45

46

47

50

52

1

2

47

48

52

50

49

51

V1H124-48

3831_00_04

Б

А

Advertising
This manual is related to the following products: