M

ASONRY

F

IREPLACE

I

NSTALLATION

:

Unless you are experienced, we recommend installation by your dealer or a

professional installer.

Install only in a masonry fireplace with a good-condition chimney at least 15 ft (4.6 m) high, both of

which have been constructed in accordance with the building code. Refer to Tables 4 and 7 for minimum

masonry fireplace dimensions. Be sure the fireplace and chimney are clean and sound without any cracks

or loose mortar. Do not remove any bricks or mortar from the fireplace.

If there is a combustible floor in front

of the masonry fireplace, the fireplace

insert must be 8” (203 mm) above the

combustible floor, and floor protection must

be provided 18” (457 mm) in front of the

fireplace insert and 8” (203 mm) to each

side of the unit. Refer also to S

PECIFICATIONS

- C

LEARANCES

T

O

C

OMBUSTIBLES

- 1200-V I

NSERT

and S

PECIFICATIONS

- C

LEARANCES

T

O

C

OMBUSTIBLES

- 1700-V I

NSERT

.

1. Remove any fireplace damper or fasten

in a permanent open position.
2. (IN CANADA) The stove is vented with

a 6” stainless steel liner that goes directly to

the top of the chimney and is covered with

a rain cap. The chimney top is sealed with

a flashing or steel plate that supports the

weight of the chimney liner. The installation

must conform to the liner’s manufacturer’s

instructions.
This fireplace must be installed with a

continuous liner of 6” diameter (CANADA

ONLY) extending from the fireplace insert to

the top of the chimney. The chimney liner

must conform to the class 3 requirements of

ULC-S635 Standard for Lining Systems for

Existing Masonry or Factory-Built Chimneys

and Vents, or ULC-S640 Standard for Lining

Systems for New Masonry Chimneys.
(IN U.S.A.)The appliance when installed,

must follow local building codes, in the

absence of local building codes, with the

current NFPA 211 Standard for Chimneys,

Fireplaces, Vents, and Solid Fuel-Burning

Appliances.

Floor

Protection

Combustible Floor

Masonry Fireplace

8"

(203 mm)

Rain Cap

Steel Plate or Flashing

Flexible or Rigid 6"

Stainless Steel Liner

Mantel

Top Facing

Damper Removed

or Fastened Open

Sheet Metal Screws

Fastening Collar to

Stainless Steel Liner

Surround Panel

USA 16” (406 mm)

CND 18” (450 mm)

Figure 10: Insert Installation into existing fireplace with

hearth.

16