Installation – Enviro Venice User Manual

Page 18

Advertising
background image

Installation

Leveling Legs

Figure 14: Removable flue collar in place.

Figure 15: Leveling legs.

S

URROUND

P

ANEL

S

EALED

I

NSTALLATION

F

OR

USA O

NLY

:

Note: Though this is an allowable installation, we do not recommend it because of the possibility of poor

draft, and therefore poor stove performance.

Before starting this type of installation refer

to I

NSTALLATION

- M

ASONRY

F

IREPLACE

I

NSTALLATION

- I

NSERT

for additional information. For

clearances refer to S

PECIFICATIONS

- C

LEARANCES

T

O

C

OMBUSTIBLES

- 1200-V I

NSERT

and

S

PECIFICATIONS

- C

LEARANCES

T

O

C

OMBUSTIBLES

-

1700-V I

NSERT

.

1. Before the face plate is installed onto

the unit, glue a 6” (150mm) wide R20

fiberglass insulation strip around the

perimeter of the back of the panels using

RTV silicon or stove gasket cement.

When the face plate is installed onto

the unit the insulation must overlaps the

fireplace opening to form a seal between

the masonry fireplace and the unit’s face

plate. Let the silicon or cement dry.

2. To make the installation of the surround

panel onto the unit easy have the unit 6”

(150mm) out from the fireplace,

3. Push the insert into the fireplace, allowing

the insulation to form a seal between

the panels and the fireplace. Tuck any

exposed insulation behind the face plate.

Figure 16: Installation with Surround Sealed.

Masonry Fireplace

Mantel

Damper Removed

or Fastened Open

Surround Panel

USA 16” (406 mm)

CND 18” (450 mm)

Insulation Around the

Back of the Face Plate

����� �� ��� ���� ���� �� ������������ ��
��������� ���� ������� ���� � �������
��������������� ���� �� �� ��� � ������� ��
��� ������ ����� �� �� �� ��� ������ ���� �����
���� ������� ��� ��� ���� ���������� ����
��� ��� ��������� �� ������� �������������
�������� ������������� ��� ���� ���������
�� ������� ��� �� ��� ������� �� ������ ��������
�� ��������

4. Screw or nail the provided metal plate with the

wording “THIS FIREPLACE HAS BEEN ALTERED

TO ACCOMMODATE A FIREPLACE INSERT AND

SHOULD BE INSPECTED BY A QUALIFIED PERSON

PRIOR TO THE RE-USE AS A CONVENTIONAL

FIREPLACE.” to the inside of the fireplace.