4 electrical connections, 5 microcem electrical connections, Electrical connections -6 – Emerson MicroCEM User Manual

Page 42: Figure 2-5, Microcem electrical connections -6, Model microcem, Instruction manual

Advertising
background image

Instruction Manual

748467-A
January 2002

2-6 Installation

Rosemount Analytical Inc. A Division of Emerson Process Management

Model MicroCEM

2-4 ELECTRICAL CONNECTIONS

NOTE

The enclosure is a NEMA 4. All entry loca-
tions must be sealed.

Connect all required signal cables to the con-
nections at the bottom of the MicroCEM. The
cable locations are indicated on the inside
bottom cover of the MicroCEM box. The ac-

tual electrical connections will be specified in
the Application Data package. All connections
are not necessary for every application.

Cable length for these signals should not ex-
ceed 3,000 feet (914 meters), to avoid exces-
sive capacitance and corresponding signal
distortion.

All electrical connections are made through
the bottom of the MicroCEM enclosure using
circular connectors.

AC POWER INPUT – J1

LAN INTERFACE – J5

ANALOG INTERFACE – J2

RS485 INTERFACE – J6

DIGITAL INTERFACE – J3

PHONE LINE – J7

RS232 INTERFACE - J4

ANTENNA – J8

Figure 2-5. MicroCEM Electrical Connections

AC POWER

INPUT

ANALOG

INTERFACE

DIGITAL

INTERFACE

RS232

INTERFACE

LAN

INTERFACE

RS485

INTERFACE

PHONE

LINE

ANTENNA

Advertising