7.10. ELECTRIC MOTOR MAINTENANCE.

the bearings of the electric motor are pre-lubricated and

are maintenance free. In normal conditions (ambient

temperature up to 30°c) replace the motor bearings after

every

12500 hours of use. In more adverse conditions

(ambient temperature up to 40°c) replace the motor

bearings after every

8000 hours of use. the bearings must be

replaced in any event after every 4 years.

fig.21

ALARM COdE CONdITIONS

Alarm

code.

Problem

Causes

Solutions

AL0

machine

stopped –

temperature

probe

anomalies.

Damage of

temperature

probe or

electric

cable.

Disconnect from the main power,

replace the temperature probe and

check the cables.

to restart the compressor press the

rEsEt button on the main board.

AL1

the

machine

stops, as

the oil

alarm has

triggered.

Excessive

temperature

of air/ oil

mix outlet

from the

screw

(105°c).

check the oil level. check if the

radiator is clean.

to restart the compressor press the

rEsEt key on the main board.

AL2

machine

stopped:

low

temperature

thermostat

tripped.

Ambient

temperature

below 0°c.

to start the machine again ensure

the compressor installation

environment guarantees a minimum

ambient temperature above - 5°c.

to restart the compressor press the

rEsEt button on the main board.

AL3

machine

stopped: the

compressor

will not start.

Emergency

button

pressed.

turn the emergency button

clockwise to unlock it. Press the

reset button on the control panel.

Wrong

rotation

direction.

switch off power to the compressor

and reverse two phases of the power

cable on the terminals for connection

of the cable line.

AL4

machine

stopped-

motor

thermal

protection

switch

tripped.

the thermal

protection

switch of the

motor has

tripped.

check if the electrical power supply

is correct, check if the three power

supply phases are more or less at

the same value. check if the cables

are firmly fitted to the terminal board.

check if the electrical cables have

melted. check if the fan in-take grill

is clean or obstructed in some way.

(paper, leaves, rags).

to restart the compressor press the

rEsEt key on the main board.

machine

stopped:

temperature

thermostat

tripped.

the internal

thermal

protection

switch of the

fan motor

has tripped.

check if the electrical power supply

is correct, check if the three power

supply phases are more or less at

the same value. check if the cables

are firmly fitted to the terminal board,

check if the electrical cables have

melted. check if the fan intake grill is

clean or obstructed in some way.

(paper, leaves, rags).

to restart the compressor press the

rEsEt key on the main board.

compressor

is running

but fails to

load.

the suction

valve has

failed to

open

check if the pressure probe is

working correctly and also if the

commanding solenoid valve (nc

solenoid valve) is working regularly.

AL5

control panel internal malfunction. (see section 5.3.9)

AL6

maintenance required. (see section 5.3.10)

7.11. dIAGNOSING THE ALARM COdE STATUS/ANOMALIES/

FAULTS.

Before doing any job on the compressor ensure that:

• The main ON/OFF switch is turned to the OFF position (“0”)

• The EMERGENCY/STOP button is pressed down into the

security position.

• The compressor is shut-off from the compressed air system.

• The compressor and the internal pneumatic circuit are

completely de-pressurised.

If you are unable to rectify the anomaly encountered on your

compressor contact your nearest authorised service centre.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK distributor, Sealey Group,

Kempson Way, suffolk Business Park

,

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

IMPORTANT WARNING - Air contaminants taken into

the compressor will affect optimum performance.

Example: Body filler dust or paint over-spray will

clog the pump intake filter and may cause internal

damage to pump/motor components.

Please note that any parts damaged by any type of

contamination will not be covered by warranty.

Original Language Version

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to

www.sealey.co.uk, email [email protected] or phone 01284 757500.

ssc12710 & ssc12710D Issue: 3 - 23/02/12