Edge Products ES3528-WDM User Manual

Page 179

Advertising
background image

Configuring Global Settings

11-7

11

address will then become the root device. (Note that lower numeric values indicate
higher priority.)
• Default: 32768
• Range: 0-61440, in steps of 4096
• Options: 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864,

40960, 45056, 49152, 53248, 57344, 61440

Root Device Configuration
Hello Time – Interval (in seconds) at which the root device transmits a

configuration message.
• Default: 2
• Minimum: 1
• Maximum: The lower of 10 or [(Max. Message Age / 2) -1]

Maximum Age – The maximum time (in seconds) a device can wait without

receiving a configuration message before attempting to reconfigure. All device
ports (except for designated ports) should receive configuration messages at
regular intervals. Any port that ages out STA information (provided in the last
configuration message) becomes the designated port for the attached LAN. If it is
a root port, a new root port is selected from among the device ports attached to the
network. (References to “ports” in this section mean “interfaces,” which includes
both ports and trunks.)
• Default: 20
• Minimum: The higher of 6 or [2 x (Hello Time + 1)].
• Maximum: The lower of 40 or [2 x (Forward Delay - 1)]

Forward Delay – The maximum time (in seconds) this device will wait before

changing states (i.e., discarding to learning to forwarding). This delay is required
because every device must receive information about topology changes before it
starts to forward frames. In addition, each port needs time to listen for conflicting
information that would make it return to a discarding state; otherwise, temporary
data loops might result.
• Default: 15
• Minimum: The higher of 4 or [(Max. Message Age / 2) + 1]
• Maximum: 30

Configuration Settings for RSTP
The following attributes apply to both RSTP and MSTP:

Path Cost Method – The path cost is used to determine the best path between

devices. The path cost method is used to determine the range of values that can
be assigned to each interface.
- Long: Specifies 32-bit based values that range from 1-200,000,000.

(This is the default.)

- Short: Specifies 16-bit based values that range from 1-65535.

Transmission Limit – The maximum transmission rate for BPDUs is specified by

setting the minimum interval between the transmission of consecutive protocol
messages. (Range: 1-10; Default: 3)

Advertising
This manual is related to the following products: