Smtp alert commands, Logging sendmail host, Table 19-13 – Edge Products ES3528-WDM User Manual

Page 312

Advertising
background image

System Management Commands

19-34

19

Example

The following example shows the event message stored in RAM.

SMTP Alert Commands

These commands configure SMTP event handling, and forwarding of alert
messages to the specified SMTP servers and email recipients.

logging sendmail host

This command specifies SMTP servers that will be sent alert messages. Use the no
form to remove an SMTP server.

Syntax

[no] logging sendmail host ip_address

ip_address - IP address of an SMTP server that will be sent alert
messages for event handling.

Default Setting

None

Command Mode

Global Configuration

Command Usage

• You can specify up to three SMTP servers for event handing. However, you

must enter a separate command to specify each server.

Console#show log ram
[1] 00:01:30 2001-01-01
"VLAN 1 link-up notification."
level: 6, module: 5, function: 1, and event no.: 1
[0] 00:01:30 2001-01-01
"Unit 1, Port 1 link-up notification."
level: 6, module: 5, function: 1, and event no.: 1
Console#

Table 19-13 SMTP Alert Commands

Command

Function

Mode

Page

logging sendmail host

SMTP servers to receive alert messages

GC

19-34

logging sendmail level

Severity threshold used to trigger alert messages

GC

19-35

logging sendmail

source-email

Email address used for “From” field of alert messages

GC

19-35

logging sendmail

destination-email

Email recipients of alert messages

GC

19-36

logging sendmail

Enables SMTP event handling

GC

19-36

show logging sendmail

Displays SMTP event handler settings

NE, PE

19-37

Advertising
This manual is related to the following products: