Edge Products ES3528-WDM User Manual

Page 98

Advertising
background image

Simple Network Management Protocol

5-14

5

linkUp

*

1.3.6.1.6.3.1.1.5.4

A linkUp trap signifies that the SNMP entity,

acting in an agent role, has detected that the

ifOperStatus object for one of its communication

links left the down state and transitioned into

some other state (but not into the notPresent

state). This other state is indicated by the

included value of ifOperStatus.

authenticationFailure

*

1.3.6.1.6.3.1.1.5.5

An authenticationFailure trap signifies that the

SNMPv2 entity, acting in an agent role, has

received a protocol message that is not properly

authenticated. While all implementations of the

SNMPv2 must be capable of generating this

trap, the snmpEnableAuthenTraps object

indicates whether this trap will be generated.

RMON Events (V2)
risingAlarm

1.3.6.1.2.1.16.0.1

The SNMP trap that is generated when an alarm

entry crosses its rising threshold and generates

an event that is configured for sending SNMP

traps.

fallingAlarm

1.3.6.1.2.1.16.0.2

The SNMP trap that is generated when an alarm

entry crosses its falling threshold and generates

an event that is configured for sending SNMP

traps.

Private Traps -
swPowerStatus

ChangeTrap

1.3.6.1.4.1.259.8.2.2.2.1.0.1

This trap is sent when the power state changes.

swFanFailureTrap

1.3.6.1.4.1.259.8.2.2.2.1.0.17

This trap is sent when the fan fails.

swFanRecoverTrap

1.3.6.1.4.1.259.8.2.2.2.1.0.18

This trap is sent when the fan failure has

recovered.

swIpFilterRejectTrap

1.3.6.1.4.1.259.8.2.2.2.1.0.40

This trap is sent when an incorrect IP address is

rejected by the IP Filter.

swSmtpConnFailure

Trap

1.3.6.1.4.1.259.8.2.2.2.1.0.41

This trap is triggered if the SMTP system cannot

open a connection to the mail server

successfully.

swMainBoardVer

MismatchNotificaiton

1.3.6.1.4.1.259.8.2.2.2.1.0.56

This trap is sent when the slave board version is

mismatched with the master board version. This

trap binds two objects, the first object indicates

the master version, whereas the second

represents the slave version.

swModuleVer

MismatchNotificaiton

1.3.6.1.4.1.259.8.2.2.2.1.0.57

This trap is sent when the slide-in module

version is mismatched with the main board

version.

swThermalRising

Notification

1.3.6.1.4.1.259.8.2.2.2.1.0.58

This trap is sent when the temperature exceeds

the switchThermalActionRisingThreshold.

Table 5-2 Supported Notification Messages (Continued)

Object Label

Object ID

Description

Advertising
This manual is related to the following products: