Silent-time, Databits, Silent-time 19-24 databits 19-24 – Edge Products ES3528-WDM User Manual

Page 302

Advertising
background image

System Management Commands

19-24

19

silent-time

This command sets the amount of time the management console is inaccessible
after the number of unsuccessful logon attempts exceeds the threshold set by the
password-thresh command. Use the no form to remove the silent time value.

Syntax

silent-time [seconds]
no silent-time

seconds - The number of seconds to disable console response.
(Range: 0-65535; 0: no silent-time)

Default Setting

The default value is no silent-time.

Command Mode

Line Configuration (console only)

Example
To set the silent time to 60 seconds, enter this command:

Related Commands

password-thresh (19-23)

databits

This command sets the number of data bits per character that are interpreted and
generated by the console port. Use the no form to restore the default value.

Syntax

databits {7 | 8}
no databits

• 7 - Seven data bits per character.
• 8 - Eight data bits per character.

Default Setting

8 data bits per character

Command Mode

Line Configuration

Command Usage

The databits command can be used to mask the high bit on input from
devices that generate 7 data bits with parity. If parity is being generated,
specify 7 data bits per character. If no parity is required, specify 8 data bits per
character.

Console(config-line)#silent-time 60
Console(config-line)#

Advertising
This manual is related to the following products: