The following port receive error information is collected by the switch:

• Receive Bad CRC Frames (RX CRC) —

The total number of frames received by the

port that were of the correct length, but contained a bad FCS value.

• Receive Oversize Frames (RX Over) —

The total number of good frames received

by the port that were of greater than the supported maximum length of 1,522 bytes.

• Receive Undersize Frames (RX Under) —

The total number of frames received by

the port that were less than 64 bytes long.

• Receive Jabber Frames (RX Jab) —

The total number of frames received by the port

that was of greater than the support maximum length and had a Cyclic Redundancy
Check (CRC) error.

• Receive Alignment Errors (RX Align) —

The total number of frames received by the

port that occurs if a frame has a CRC error and does not contain an integral number
of octets.

• Receive Frames Lost (RX Lost) —

The total number of frames received by the port

that were lost because of buffer overflow in the switch.

P

ORT

M

ONITORING

D

ISPLAY

K

EYS

Table 12-2

describes the keys used to control the displays that appear when you issue

any of the

show port

commands.

Table 12-2: Port Monitoring Display Keys

Key(s)

Description

U

Displays the previous page of ports.

D

Displays the next page of ports.

[Esc] or [Return]

Exits from the screen.

0

Clears all counters.

[Space]

Cycles through the following screens:

Packets per second

Bytes per second

Percentage of bandwidth

Available using the

show port

utilization

command only.

Summit.bk : 12STATUS.FM Page 9 Thursday, June 18, 1998 9:27 AM