Area method interval – EDGE Tech QL Series User Manual

Page 46

Advertising
background image

46

QL Series User Guide

Use the supplied cleaning pen or 70%
isopropyl alcohol on a cotton swab to
clean the print elements from end to end
(the print elements are located in the thin
gray line on the printhead).

Printhead
(Figure 19)

Peel bar
(Figure 19)

Clean thoroughly with the cleaning pen
or 70% isopropyl alcohol and a cotton

Area

Method

Interval

As needed

After every five
rolls of media
(or more often,
if needed)

Platen
Roller
(Figure 19)

Tear bar
(Figure 19)

Scraper
(Linerless units
only) Figure 19a

Clean thoroughly with the cleaning pen or
70% isopropyl alcohol and a cotton swab.

Clean thoroughly with the
cleaning pen or 70% isopropyl
alcohol and a cotton swab.

Exterior

Interior
(Figure 19)

As needed

After every five
rolls of media
(or more often,
if needed)

After every five
rolls of media
(or more often,
if needed)
Linerless media
requires more
frequent
cleaning

Platen Roller
(Figure 19a)

Interior
(Figure 19a)

Water-dampened cloth

Brush/air blow. Ensure the Bar Sensor, Gap
Sensor and Label Present Sensor windows
are free of dust.

Units with linerless platens:
Clean inside surfaces of Media supports &
Media Support Disks with the supplied
cleaning pen or 70% isopropyl alcohol on a
cotton swab.

QL220 Cleaning

Rotate the platen roller and clean it
thoroughly with the cleaning pen or 70%
isopropyl alcohol and a cotton swab.

Units with linerless platens: Rotate
platen & clean bearing points only. Avoid
use of alcohol on the surface of linerless
platens!

Advertising